Dr. Somali Nguyen explains how to perform an ocular ultrasound using a high-frequency linear probe for detailed imaging of the eye. To protect the patient, he recommends placing a Tegaderm over the eye before applying ultrasound gel. The probe is positioned gently over the gel without direct contact with the eye. He demonstrates both transverse and sagittal views, guiding the viewer through visualization of the anterior and posterior chambers, lens, retina, and optic nerve. Eye movement is assessed by having the patient look in multiple directions to ensure full anatomical coverage and functional integrity.